EQUIPMENT
PBI Air Sampler
Your Partner in Environmental Microbiological Monitoring
“A microbial air sampler is an instrument to collect the air-borne microorganism”
Basic Principles:
- Uses simple and ready-to-use agar contact plates for air and surface sampling.
- Sample a known volume of air for a variable time to achieve a range of sampling volumes.
- Aspirate air in laminar flow with sufficient velocity to impact airborne microorganisms onto agar surface for incubation and evaluation.
- Establish data on the microbial level in the selected environments to monitor sanitization trend and control contamination.
- Organize sequential sampling to obtain a more
Popular Features of SAS Products:
- Lightweight, Compact, Portable and Remote
- Durable and Rugged
- Optimized Performance and Quality Assurance
- Brand Confidence and Product popularity
- International Standard and Worldwide Service and Support Network
- 25 years of Experience in 5 Continents
- Largest and Complete Range of Options
- Extensive Settings and Configurations
- Versatile Operating Range
- Total Traceability and Multi Language Options
Other Features:
- Flexibility to use either RODAC Contact Plates or Standard Petri Dishes is required.
- Inter-changeable heads and holders
- Optional disposable heads
- Fast flow rate of 180 l/min enables 10 m3 air sampling to be completed within 1 hr.
- Sampling large volumes of air a short period of time (1 cubic meter sampling in less than 6 minutes)
- Sequential sampling for “in operation” monitoring according to UPS recommendations
- Pyramid shape for better stability in vertical stand-alone position and enhanced ergonomics.
- Bi-directional communication (SAS Super Network) between one or more SAS Samplers.
Applications
- Microbiological monitoring of clean room and other controlled environments and critical processes.
- Facility Certification for Compliance Regulations
- Quality Control and Inspection for Medicinal Products
- Performance monitoring, Evaluation Verification and Trouble shooting
- HACCP/GLP/GMP Application and Assessment
- Air/Surface Contamination
- Air Quality and Bio-aerosol Assessment in the Indoor environment
- Environmental Microbiology and Biotechnology Research and Validation
- For the Pharmaceutical, Healthcare and Food Industries
SAS Super & Super ISO
- Performance in compliance with ISO 14698‐1
- USP Chapter <1116> and 21‐CFR 11 compliant
- Up to 300 sampling cycles memorized
- Up to 10 sequential sampling cycles for “in operation” monitoring according to USP recommendations.
- Delay start of up to 60 minutes.
- Interval sampling with fully programmable parameters for “in operation” monitoring
- Sampling rate is constantly and accurately maintained by speed sensor ‐ incorrect aspiration automatically aborts cycle
- Additional Flexibility to use 55mm Contact Plates (U.S., or European made), 84 mm Maxi Contact Plates or 90mm standard Petri Dishes.
- Fully autoclavable heads
- Choice of flow rate, high speed sampling and reduced sampling time range from 360 / 180 / 100 liters air flow per minute (Example: 1000 liters in less than 3 min with SAS SUPER 360 model)
- Autonomy is ideal for low contamination environments such as the Clean Room where it is necessary to effectively test a large volume of air.
- Advanced electronics technology for reliable results in different operating conditions
- Easy communication: infrared transfer of sampling data to PC or printer
- Bi‐directional port to input and output data to a central unit from 1 to 24 samplers
- Design avoids turbulence in unidirectional air flow and re‐aspiration of tested air in accordance with ISO specifications
- Automatic time calibration reminder
- Sampler can be operated whilst attached to mains. Suitability in isolators.
- Large LCD with illuminated touch screen panel
- Certified aspirating head in aluminum, stainless steel or plastic “Disposable Head”
- All operator commands via touch / keypad for easier cleaning
Infrared remote control (optional)
SAS Isolators
- Specifically designed for critical air monitoring inside isolator and in barrier environments.
- Programmable unit remains outside the controlled area
- Independent sampling head may be positioned anywhere in the isolator.
- Complete isolation of controller from controlled environment
- Fully sanitizable sampling unit
SAS Super 360
- Over 20 m3 of air/hour monitoring autonomy is ideal for low contamination environments such as the Clean Room where it is necessary to effectively test a large volume of air.
Pinocchio II
- Self contained unit consisting of connections, air flow meter, pressure gauge, tap, funnel head complete with plate housing
- Unit requires no power and is fully transportable
- It can collect air samples either on 55 mm contact plates (RODAC) or Standard 90 mm Petri dishes
- It is sterilisable
- It is calibrated according to International Standard
Services and Support
- Complete Validation Documentation
- On-Site Training
- Official NIST Traceable Calibration
- > 100 Application Notes
- SOP Documentations
- IQ, OQ, PQ Qualifications












English